What Is Total Dynamic Head (TDH)?
The total dynamic head is the total resistance an engine pump must overcome to move water from the source to the point of use. It is measured in metres.
We talk in metres of head rather than pressure for a good reason. The head stays the same whatever you are pumping, so it lets you read a pump curve and compare pumps on a level field. Pressure changes with the fluid. The head does not.
TDH also determines the pump’s workload, which sets its power and performance curve. By getting the right TDH, your pump can run efficiently for yours. If you get it wrong, you’re posing risks to efficiency, safety and regulation — or, put simply, you’ll find yourself frustrated when water pressure drops off every time two outlets are running at once.
The Components of Total Dynamic Head
TDH is the sum of three parts: static head, friction loss and pressure head. Work each one out and add them up, and you have your figure.
Static Head
The static head is the vertical distance the pump lifts water, measured from the water level at the source to the final discharge point. Two things go into it: the lift from the water level to the pump, and the height from the pump to the discharge point.
Remember to measure from the water level, not the ground. A bore pump sitting 40 metres below ground that discharges into a tank 2 metres above the surface works against 42 metres of static head. If you miss the discharge height, you will have already undersized the pump before you start on anything else.
Friction Loss
Friction loss is the head the pump yields to the pipe walls and every fitting along the way. The pipe diameter, length, material and flow rate all factor into the amount of friction loss you need.
The pipe diameter is the most important factor, and it is where people often make mistakes. Push 60 litres a minute through 100 metres of 25 mm poly and you can lose more than 40 metres to friction. Run the same flow through a 50 mm pipe, and that drops to under a metre. Going up one pipe size often does more for performance than going up a pump size.
Material counts too. PVC and poly run smoother than old galvanised steel, so they cost you less head over the same distance. Fittings also add to the total. The simple way to handle them is the equivalent length method, where each fitting counts as a set length of straight pipe. A 90-degree elbow is worth roughly a metre, and a tee around two.
Add those lengths to your pipe run, then read the total friction off a friction loss chart or calculator.
Pressure Head
Pressure head is the working pressure the system needs at the outlet, converted into metres so you can add it to the total. Ten metres of head is roughly one bar, or 100 kPa.
To convert PSI to metres, multiply by about 0.7 or divide by 1.45. A house that needs 40 PSI at the tap is asking for about 28 metres of head. If the system runs a pressure tank, set this figure to the cut-out pressure you want the pump to reach.
Step-by-Step TDH Calculation
- Measure static head: Find the vertical distance from the source water level to the discharge point. Add the suction lift and the discharge height.
- Calculate friction loss: Measure the full pipe length of every horizontal and vertical run. Note the diameter and material. Read the friction loss for the straight pipe off a chart, then add the equivalent length for your elbows, tees and valves and read the total.
- Add pressure requirements: Decide the working pressure the outlet needs, then convert it to metres.
- Add a safety margin: Add 10 to 15 per cent to cover what you cannot measure exactly. Pipes roughen with age, demand creeps up and charts are approximations.
- Total it up: Add the lot together.
TDH = Static Head + Friction Loss + Pressure Head + Safety Margin
Worked Example: Rainwater Tank to House
Take a rainwater tank feeding a house, a common job on any rural or semi-rural block.
- Required Flow: 40 litres per minute (enough to run a shower and a tap together)
- Static Head: 6 metres(the highest outlet sits 6 metres above the tank’s low water level)
- Friction Loss: 4 metres (~3 metres for 40m of 32mm poly, plus 1 metre for elbows/valves)
- Pressure Head: 28 metres (40 PSI at the outlet)
- Safety Margin: 4 metres (10% of the running total)
Add them up: 6 + 4 + 28 + 4 = 42 metres.
So you need a pump that delivers 40 litres per minute at 42 metres of head. Pick one whose curve sits comfortably above that point at your flow.
Browse Maxijet’s pumps suited to this duty.
Common Pump Head Calculation Mistakes
The same errors tend to prop up over and over, but most of these are easy to avoid once you know to look for them:
- Leaving friction loss out altogether and sizing on static head alone.
- Using the wrong roughness value for the pipe material.
- Forgetting the fittings, which add up fast on a long run with plenty of bends.
- Ignoring elevation changes hidden in a horizontal run across sloping ground.
- Measuring from ground level instead of the water level.
- Converting pressure to head the wrong way.
- Skipping the safety margin, which leaves the pump running flat out with nothing in reserve.
How to Read a Pump Curve
A pump curve plots flow against the head. Find your TDH on the vertical axis and your required flow on the horizontal axis, then see where they meet. That intersection is the operating point.
What you want is for that point to sit in the middle of the curve, near the pump’s best efficiency point. Land it too far left, and the pump will be working against too much head and run hot. Too far right and it is pushing too much flow with little pressure to spare.
On suction jobs, check the net positive suction head the pump needs against what your installation can supply, or you risk cavitation.
Get Your Pump Sizing Right
Accurate pump head calculation is what separates a pump that runs quietly for a decade from one that fails after only some time of use. Measure the static head, work out the friction loss, add the pressure you need and a safety margin, then match that total dynamic head to the pump curve at your flow.
Need a hand checking a TDH figure or selecting a pump to suit it? Request technical advice from our team or browse pump specifications.
Frequently Asked Questions
- What is the difference between static head and dynamic head?
- Static head is the vertical lift alone, measured with no water moving. Dynamic head adds the losses that only show up under flow, mainly friction in the pipe and fittings plus the working pressure you need at the outlet. Total dynamic head is the full figure on which you size the pump.
- How do you convert PSI to head in metres?
- Multiply the PSI by about 0.7, or divide it by 1.45. So, 40 PSI is about 28 metres of head. As a quick check, 10 metres of head is about 1 bar or 100 kPa.
- Why size a pump on head instead of pressure?
- Head is independent of the fluid, so it lets you read any pump curve and compare pumps directly. Manufacturers publish performance as flow against head for the same reason: pressure depends on what you are pumping, while head does not.
- How much safety margin should I add to a TDH calculation?
- Usually 10 to 15 per cent. It covers pipe roughening with age, friction charts being approximate and demand growing over time. It is not a licence to oversize; it is just a sensible buffer to ensure the pump is not running at its limit from day one.